Item | Technical Requirements | Note | |
Input Feature | AC input voltage | 400±15% VAC | System Input Voltage |
AC Input Frequency Range | 40-60Hz | ||
Power Factor | ≥0.99 | 50% or higher load | |
AC Input Mode | Three-phase Five-ware system | 3P+N+PE | |
Output Feature | Output Voltage Regulating Range | 150-750VDC | Could achieve continuous regulating by monitoring means |
DC Output Charging Interface | Refer to IEC62196-3-2011 | ||
Stable Voltage Precision | ≤±0.5% | In Full Output Range | |
Stable Current Precision | ≤0.5% | ||
Voltage Error | ≤±0.5% | ||
Current Error | ≤±1% Output DC Current≥30A ≤±0.3A Output DC Current<30A |
||
Average Flow Unbalance Degree | ≤±5% | ||
Average Efficiency | ≥95% | 50% or higher load | |
Input Current Harmonic Wave | ≤5% | ||
Other Feature | Noise | ≤65dB | |
RCD Protection | YES | ||
Power Frequency Withstand Voltage | 2500V AC-3500V DC | ||
Insulation Resistance | ≥20MΩ | Test Voltage 1000V DC | |
IP Class | IP54 | ||
Connector Cable Length | Standard Length is 5M | ||
Environmental Protection | Meet 2011/65/EU |